NAUTILUS INSPECT
AI v2.4
FLEET OVERVIEW/PSC & CLASS REPORT AUDIT DESK

Port State Control & Class Survey Auditor

Automated deficiency parsing, Action Code 17/30 risk extraction, and detention mitigation roadmaps

Document Source:
Select an authentic Port State Control or Class survey report:
M/V PACIFIC HORIZON
Clearance
Paris MoUPort of Rotterdam, Netherlands
2026-08-144 Deficiencies
M/V BALTIC GUARDIAN
Detained
Paris MoUPort of Piraeus, Greece
2026-07-119 Deficiencies
MT OCEAN TITAN
Clearance
USCG Form 835Houston Port Authority, USA
2026-09-021 Deficiencies
Paris MoU
Detention Notice Issued (Code 30)

M/V BALTIC GUARDIAN — IMO 9315842

Port of Piraeus, Greece • Surveyor: N. Kostopoulos (Hellenic Coast Guard PSC)2026-07-11

DETENTION ISSUED (Code 30). Emergency fire pump failed to build pressure; 15 ppm bilge separator alarm bypass detected; life raft painter not properly connected to hydrostatic release.

Itemized Deficiencies & Statutory Non-Conformities

Assigned Paris MoU deficiency codes, IMO convention references, and root-cause analyses

Action Code 30Code 04103(Emergency systems)

Emergency fire pump - Priming mechanism defective; unable to produce required 2 jets of water

SOLAS 74/Reg. II-2/10.2.2.3
Root Cause Analysis:

Impeller key sheared inside centrifugal casing during weekly drill test.

Remedial Measure & Class Action:

Disassemble pump casing in workshop, fit new stainless steel impeller key, demonstrate 4 bar pressure at bridge wing.

Action Code 30Code 14108(MARPOL Annex I)

15 ppm Bilge Alarm - 3-way diversion valve solenoid mechanically blocked with wooden wedge

MARPOL 73/78 Annex I / Reg. 14
Root Cause Analysis:

Deliberate tampering by crew to avoid recalibrating optical turbidity sensor.

Remedial Measure & Class Action:

Remove override, recalibrate 15ppm sensor with certified calibration fluid, log in Oil Record Book Part I.

Action Code 30Code 11117(Life saving appliances)

Inflatable life rafts - Hydrostatic release unit (HRU) expired by 4 months

SOLAS 74/Reg. III/13.4
Root Cause Analysis:

Safety inventory tracker not updated following crew turnover.

Remedial Measure & Class Action:

Supply and fit 2 new Hammar H20 HRUs with valid certificates of conformity.

Action Code 17Code 07115(Fire safety)

Fire dampers - Ventilation fire dampers for galley seized in open position

SOLAS 74/Reg. II-2/9.7.3
Root Cause Analysis:

Grease accumulation from cooking fumes baked onto damper spindle blades.

Remedial Measure & Class Action:

Chemical degreasing of ductwork, overhaul damper linkage, confirm free fall counterweight operation.

Showing 4 of 4 deficiencies