FLEET OVERVIEW/IMO STATUTORY CHECKLISTS

IMO, SOLAS & MARPOL Inspection Checklists

Surveyor-grade verification for Life-Saving Appliances (LSA), Firefighting, Hull, and MLC

Active Survey: M/V PACIFIC HORIZON
Flag: Panama

Audit Compliance Rating

82%7 of 11 checkpoints verified satisfactory
Passed
7
Compliant
Deficiencies
4
Code 16 / 17
Critical Fails
0
Detention (Code 30)
Unchecked
0
Pending Audit
Status Filter:
SOLAS-III-20
SOLAS Safety & LSA
SOLAS Ch. III Reg. 20.4

Are lifeboat launching appliances, winches, falls, and dynamic brakes tested and within certification limits?

Falls renewed every 5 years or reversed at 30-month intervals. Winch brake serviced annually per MSC.1/Circ.1206.

SOLAS-III-13
SOLAS Safety & LSA
SOLAS Ch. III Reg. 13.4

Are hydrostatic release units (HRUs) for inflatable liferafts correctly connected with weak link and unexpired?

Weak link properly tied to painter; HRU within 2-year expiration service window or replaced.

SOLAS-II2-10
Fire Protection & FFE
SOLAS Ch. II-2 Reg. 10.2.2.3

Does the emergency fire pump start immediately from cold condition and maintain required dual hose nozzle pressure?

Delivers two 12mm jets of water at minimum 2.7 bar to the highest fire hydrants.

SOLAS-II2-04
Fire Protection & FFE
SOLAS Ch. II-2 Reg. 4.2.2.5.2

Are high pressure fuel injection lines shielded, jacketed, and equipped with leakage alarms?

All diesel engines >375 kW must have jacketed high-pressure fuel lines draining to monitored leak tank.

SOLAS-II2-09
Fire Protection & FFE
SOLAS Ch. II-2 Reg. 9.7

Can all ventilation fire dampers, engine room funnel dampers, and galley extraction dampers close tight remotely?

Manual and remote pneumatic/counterweight trips must snap shut without sticking.

MARPOL-I-14
MARPOL & Pollution
MARPOL Annex I Reg. 14

Is the 15 ppm Oily Water Separator (OWS) and 3-way automatic stopping valve operational without bypass?

Effluent oil content must not exceed 15 ppm; discharge terminates automatically if threshold exceeded.

MARPOL-VI-13
MARPOL & Pollution
MARPOL Annex VI Reg. 18

Are Bunker Delivery Notes (BDNs) retained on board with MARPOL low-sulfur (<0.50% / <0.10% ECA) verification?

BDNs and representative fuel samples kept on board for minimum 3 years.

ILLC-66-15
Hull & Loadline
Load Lines 1966 Reg. 15

Are cargo hatch cover rubber gaskets, compression bars, drains, and cross-joint cleating mechanisms weather-tight?

Hatch covers must prevent water ingress under green sea loads; zero continuous light or water penetration.

IACS-Z10-BULK
Hull & Loadline
IACS UR S18 / SOLAS XII/6

Are cargo hold transverse bulkheads, stool connections, and side frames free of critical structural fractures?

Wastage must not exceed class allowable diminution limit; zero propagating fatigue cracks.

MLC-2006-A3
MLC 2006 & ISM Code
MLC 2006 Title 3

Are crew accommodation, galley hygiene, potable water supply, and hospital medical locker fully compliant?

Clean living spaces, potable water tested monthly, medicine chest certified per WHO guidelines.

ISM-CODE-10
MLC 2006 & ISM Code
ISM Code Section 10

Is the Safety Management System (SMS) maintenance log up-to-date with critical equipment test records?

Planned Maintenance System (PMS) overdue work orders must not exceed 5% of critical items.

Total Checklist Items: 11 • Checked: 11